Plant-floor computing, explained.
Practical answers for the engineers who specify, install and maintain industrial PCs, edge devices and the software that runs on them.
Read the latest articlesLatest articles
Troubleshooting
LatestProcess Historian plant hierarchy error after project upload
After a new project was uploaded into an existing PCS 7 V9.0 SP3 hierarchy, the Information Server Plant Structure Dashboard fails to build the plant hierarchy and manual report retrieval returns an error while scheduled reports keep working. Treat both as leads from the same change, capture the exact log entries and compare the scheduled and manual report paths before touching downloads or memory resets.
Troubleshooting
Groov RIO Data Services start and stop from Node-RED
To start or stop groov RIO Data Services from Node-RED, send an HTTP POST with an empty payload to /manage/api/v1/dataservice/start or /manage/api/v1/dataservice/stop. The reply can be slow and sometimes returns HTTP 503 Service Unavailable, so the flow needs bounded retry logic. Data Services is the device's native MQTT and OPC UA subsystem, separate from the Node-RED runtime.
Troubleshooting
WinCC can't access database after power loss: DCF and reset steps
After a power loss, a WinCC station that reports "Microsoft SQL Server can't access the database" is usually fine at the database level. Run reset_wincc.vbs and reboot first; if the error remains, stop the SQL Server (WINCC) service, delete the project's .dcf file, restart the service, and let WinCC recreate it before changing any access rights.
Selection guide
What decides an IIoT platform choice with mixed PLC brands
The platform brand is the last decision, not the first. Size the data path first: multiply tag count by update rate to get payload throughput, check it against each controller's communication budget and the uplink bandwidth, require OPC UA or per-brand drivers plus outbound-only MQTT with buffering, and shortlist only platforms that meet those numbers.
Troubleshooting
Why node-red-contrib-iiot-opcua installs with 3 npm vulnerabilities
The install did not fail: the transcript shows npm completing a global install, and the three reported vulnerabilities are audit findings on a dependency tree no update will change, because node-red-contrib-iiot-opcua is deprecated and closed since April 2020. Back up the flows, run npm audit fix followed by npm audit, and migrate new work to node-red-contrib-opcua after checking node compatibility.
Troubleshooting
Why Node-RED reads OPC UA data but gets no alarms or events
Reading OPC UA variables in Node-RED proves the session works; it proves nothing about alarms, because values and events travel as separate subscriptions. Wire an OpcUa-Event node to the Server object, filter on the base event type, set the client action to events, and confirm the endpoint actually exposes event notifiers; a Classic AE-only source needs an AE-to-UA gateway.
Troubleshooting
Why the InfluxDB node install fails in Node-RED behind a proxy
A ping from the edge box proves only name resolution and ICMP. The palette install fetches packages over HTTPS with npm, and npm on the device does not inherit the proxy configured on the company modem, so the install fails while the same install works on a Windows PC. Set the proxy in npm on the device, in the account that runs the install, then retry and restart Node-RED.
Troubleshooting
Process Historian GrantLicense Failed means a license problem
GrantLicense Failed in the Process Historian 2014 diagnostic console is a licensing fault, not a database fault: the historian could not obtain its runtime entitlement at startup. Capture one controlled startup, read the Automation License Manager records for that attempt, correct the license condition, then plan the move to 2014 SP3 UPD6 on a supported operating system.
Explainer
What an internal rental license means on a historian MLFB
A historian version absent from catalog search can still be orderable through the local dealer. The only publicly listed MLFB for the newer release was a one-user rental designated an internal license, not the perpetual server product, so it must not be ordered for a customer deployment without written confirmation of its terms.
Troubleshooting
Suspended and locked on a redundant Process Historian pair
The locked server is protecting its archive because its storage volume has reached its capacity limit, and the inactive compression is a symptom of the suspended server processing nothing. No state switch works until free space returns. Free space through retention and archive tools, migrate only by the documented procedure for your installed version, then recover redundancy with the storage-healthy server first.
Troubleshooting
Why S7 Connector status turns bad after one minute
A status dot that is green and then turns bad after about one minute means the connector established the connection but lost acquisition or Databus publication. Test the three boundaries separately: PLC session and tag reads, Databus credentials and publish permissions, and an exact topic match including every segment.
Comparison
Redirecting PLC data logging to an external industrial PC
Keep the controller logging to its SD card and move completed log files to the PC with a periodic push or pull; collect live OPC UA values on the PC only when losing records during outages is acceptable. The tag count, rate, record size, retention and worst outage fix the storage, and the worked example sizes it.