Backing up Industrial Edge Management VMs with snapshots

Edge computing and IIoT Published 5 min read

Short answer

Take the snapshot with the Industrial Edge Management VM powered off, through the hypervisor user interface. Keep it only for the maintenance window: VMware documents a 72-hour maximum and states that snapshots are not backups. Validate the update, delete the snapshot, and use a VM clone for long-term retention.

On this page
  1. Decide first: snapshot for the window, clone for keeps
  2. Shut the IEM VM down cleanly
  3. Take the snapshot
  4. Worked example: window length and delta size
  5. Restore the IEM from a snapshot
  6. Pitfalls that turn a snapshot into data loss
  7. Verify one full cycle before you rely on it
  8. Questions asked

A snapshot of the virtual machine is the right tool for backing up an Industrial Edge Management (IEM) instance across one maintenance window: shut the VM down through the user interface, select it, open VM on VMware Workstation Pro or Actions on ESXi, and run Snapshot > Take Snapshot. That is the whole procedure, and its limit matters more than its steps. VMware's snapshot best practices set a maximum of 32 snapshots in a chain, say not to run a VM on a snapshot for more than 72 hours, and state plainly that snapshots are not a backup of the virtual disks. So the snapshot is your rollback point for an IEM update or a patch test, and a VM clone is your long-term copy. Both procedures, the 72-hour rule and the arithmetic that decides snapshot versus clone, are below.

Decide first: snapshot for the window, clone for keeps #

What you need Mechanism Why
Rollback point before an IEM update Snapshot Fast to take and to revert, deleted after validation
Quick failsafe before a patch or application test Snapshot One revert returns the VM to the pre-test state
Long-term retention of a known-good IEM VM clone Independent copy, no delta file, no chain dependency

Write the intended retention down before you touch the hypervisor. If it is one update window, a snapshot is enough. If it is anything longer than one window, plan a clone in addition to the snapshot, because a snapshot lives on the same datastore as the base disk and dies with it. The steps below do not depend on the host hardware: whether the IEM VM runs on a workstation or on a fanless industrial mini PC in the cabinet, the hypervisor menu is the same.

Shut the IEM VM down cleanly #

The documented guidance for the IEM is explicit: to avoid errors, take snapshots only while the VM is powered off through the user interface. A powered-off VM has no memory state and no in-flight disk writes, so the snapshot holds a file-system-consistent image of the IEM and its container platform.

  1. Pick the maintenance window and tell everyone who deploys to the IEM. Devices on the plant floor keep running their deployed applications while the IEM is offline; only management functions pause.
  2. Shut the guest operating system down from inside the VM or with the hypervisor's guest shutdown. Never cut power hard.
  3. Confirm the inventory shows the VM as powered off, and that the IEM web interface no longer responds on its address.

Take the snapshot #

  1. Select the virtual machine that runs the IEM.
  2. Click VM (Workstation Pro) or Actions (ESXi), then Snapshot > Take Snapshot.
  3. In the Name field, enter a unique name that encodes the date and the reason, for example iem-pre-update-2025-04-14. Ambiguous names are how the wrong snapshot gets restored.
  4. In the Description field, record what changed around it: the IEM version being replaced and the maintenance ticket.
  5. Click Take Snapshot.

Check: the snapshot appears in the snapshot manager under the name you entered, with a timestamp matching the action.

Worked example: window length and delta size #

This example is illustrative; measure your own IEM's write rate before trusting the size. Suppose the VM has a 100 GB base disk. You snapshot it on Monday at 07:00 before an update, and validation finishes on Tuesday at 09:00. Retention is 26 hours, inside the 72-hour limit. Suppose the IEM and its applications write 3 GB of new or changed blocks in that window: the delta file then holds roughly 3 GB, and the datastore needs 103 GB free for that VM plus your normal headroom. Now suppose validation slips to Thursday at 07:00. Retention is 96 hours, past the limit. The decision is fixed: delete that snapshot, and take a fresh one when work resumes, or clone the VM instead of holding the old snapshot. Chain arithmetic works the same way: keeping one snapshot from each of four past update cycles gives a chain of four, well inside the supported 32, but every open snapshot adds overhead, so delete rather than stack.

Restore the IEM from a snapshot #

  1. Select the IEM VM and power it off, using the same guest shutdown as before.
  2. Click VM or Actions, then Snapshot > Revert to Snapshot for the latest one, or Snapshot > Manage Snapshots to pick a specific one.
  3. Click Yes to confirm.
  4. Power the VM on and open the IEM web interface; it should show the configuration as it was at snapshot time.

Reverting discards every write made after the snapshot, including IEM configuration changes and device onboardings completed since then. Export anything you might need before you revert; there is no undo for a revert.

Pitfalls that turn a snapshot into data loss #

  • Leaving the snapshot in place after a validated update: the delta keeps growing for as long as it exists. Delete it once the update is confirmed good.
  • Stacking snapshots instead of deleting: a longer chain slows every disk operation on that VM, the same disk-bound behavior behind many slow automation VMs on a Windows 11 host.
  • Treating the snapshot as the only copy: the delta depends on the base disk in the same datastore, so a datastore failure takes both.
  • Snapshotting a running VM: the documented guidance warns this causes errors, and the image may not be consistent.
  • Slipping past 72 hours: treat that figure as a hard stop, not a suggestion.

Verify one full cycle before you rely on it #

  1. Power off the IEM VM and take a snapshot with a unique name; confirm it is listed in the snapshot manager.
  2. If the retention justifies it, create a clone as well; confirm the clone is registered as a separate virtual machine.
  3. Power on the original, make one small harmless change, then revert to the snapshot; confirm the change is gone.
  4. Power on again and open the IEM web interface; confirm login and the pre-snapshot configuration. If the VM is unreachable from some VLANs after power-on, that is a network problem, not a snapshot problem.
  5. Delete the snapshot once the maintenance window closes; confirm the snapshot manager is empty.

Run this cycle once on a quiet day. The day you need the rollback is not the day to learn that your revert path or your datastore space was wrong.

Questions asked

Do my edge devices keep running while the IEM VM is powered off?

Yes. The IEM is the management plane: devices continue running the applications already deployed to them while it is offline. What pauses is deployment, updating and configuration through the IEM. Schedule the window so nobody needs to push an app or a device change during it, and the power-off step costs you nothing operationally.

Can I copy the snapshot files to another disk as a backup?

No. A snapshot consists of a delta file plus its base disk, and the delta is unusable without that exact base disk. Copying only the delta files gives you nothing restorable. For a copy that lives somewhere else, clone the whole VM or export it in full, then store the clone on separate storage.

What is the difference between Revert and Delete in the snapshot manager?

Revert to Snapshot moves the running VM back to the recorded state and discards later writes. Delete removes the snapshot point and merges the delta writes into the base disk; it changes nothing on the currently running VM. After a validated update, Delete is the right action, not Revert.

Does the snapshot capture the IEM's internal data?

Yes, as long as that data lives on the VM's virtual disks. The snapshot records the disks at the moment of power-off, so the IEM's configuration and history on those disks are included. Anything the instance writes outside its own virtual disks, such as a share on another server, is not covered and needs its own copy.

Keep reading

  • Troubleshooting

    Fixing a Docker shared library error on an edge PC

    A container on an edge PC that exits with an error while loading shared libraries was built for a different controller firmware generation than the one installed. Pull the image revision rebuilt for your firmware, recreate the container, and verify with ldd, the linker cache and a restart-count check. Never symlink across major library versions: on a machine driving physical outputs, a mismatched library produces wrong I/O data instead of a clean error.

    Edge computing and IIoT

  • Troubleshooting

    Ignition Edge stuck starting after a Java trust store corruption

    The gateway page stays at Gateway is starting because module initialization dies when Java cannot build its default SSL context — wrapper.log shows java.security.NoSuchAlgorithmException for DefaultSSLContext under SunJSSE. Copy cacerts and cacerts.bak out of lib\runtime\jre-win\lib\security in the installation the service runs, rename cacerts.bak to cacerts, restart the service, and the gateway comes up.

    Edge computing and IIoT

  • How-to

    Install licensed software on an industrial edge PC

    Install vendor-licensed container software on an industrial edge PC by passing four gates in order: a purchased license with the installer obtained only from the vendor, a verified Docker engine, an installer build that matches the CPU, and a proven open-internet path before the pull. Vendor guidance budgets the install command at 30 minutes to 1 hour; at a 5 Mbit/s link a 2 GB payload alone needs about 53 of them.

    Edge computing and IIoT

Setting up Sparkplug B on an edge gateway controller