Selection guide
Choose a firewall VPN for an industrial remote access router
Short answer
The Ewon tunnel is OpenVPN, initiated outbound. For Ewon-client-to-firewall-server mode, buy a firewall with an OpenVPN server role; IPsec or PPTP support is irrelevant. If you only use Talk2M, the firewall needs no VPN role at all, just outbound rules for *.talk2m.com on the ports in KB-0209, which requires hostname and wildcard address objects.
On this page
The protocol is OpenVPN. An Ewon router builds its tunnel as an OpenVPN client, over connections it initiates itself, so the firewall you buy for the Ewon client, firewall server design must offer an OpenVPN server role; IPsec, PPTP or L2TP capability says nothing about Ewon compatibility. If you only need Talk2M access, the firewall needs no VPN feature at all: it must permit outbound traffic to *.talk2m.com on the ports listed in KB-0209, which means hostname and wildcard address objects. Below are the requirement list, the addressing arithmetic that decides whether a standing tunnel actually carries traffic, and the decision for each deployment.
What the tunnel speaks #
The Ewon device uses OpenVPN as its VPN protocol, and it uses outbound connections only. That pair of facts sets what the far end must be:
- In Talk2M service mode, the Ewon is the client and the Talk2M infrastructure terminates the tunnel. Your firewall is a transit device, not a VPN endpoint.
- In the design you are buying for, Ewon client and firewall server, your firewall terminates the tunnel and the Ewon dials it like any third-party OpenVPN server.
The second design is a documented pattern, not an improvised one. HMS Networks publishes How to connect your Ewon to Third Party OpenVPN Servers, covering the settings Flexy and Cosy devices use against a third-party server, and a separate guide to configuring pfSense as an OpenVPN server for Ewon devices in bridged mode. For fleets, its Anybus Defender is documented as the OpenVPN server with Flexy and Cosy+ devices as clients. On the machine side, this is the same outbound tunnel behind connecting an SLC 5/03 PLC to an industrial remote access router.
The two designs and what each asks of the firewall #
Talk2M first, because it changes the purchase. Since the Ewon only initiates, a stateful firewall needs no inbound rule at all; return traffic matches the outbound session. Do not replace a firewall merely because it lacks inbound VPN-server configuration, because for this path none is required. You only touch it when egress is filtered: then the rule set is the addresses and ports listed in KB-0209, Talk2M used addresses and ports, and the destination is a wildcard, *.talk2m.com. A firewall whose policy objects are limited to fixed numeric IPs cannot express that rule; alphanumeric hostnames with wildcard matching are the deciding feature. Where the path also crosses corporate proxies, the egress discipline is the one covered in remote SCADA access through firewalls and proxies.
The direct tunnel turns your firewall into the server. The Ewon still initiates, so the only listening exposure is the OpenVPN server port on the firewall's public side, and the corporate end must be able to issue the certificates, credentials and profile the Ewon client loads. A shared protocol label is not an interoperability guarantee: match the server's transport, authentication and certificate settings against what the Ewon supports before ordering. One safety note covers both designs: never forward unsolicited inbound ports to the Ewon itself, because it functions entirely through sessions it starts, so forwarding adds attack surface and gains nothing.
Firewall requirements at a glance #
| Requirement | Why the Ewon needs it | What fails without it |
|---|---|---|
| OpenVPN server role | The Ewon connects as a client and the corporate end terminates | IPsec-, PPTP- or L2TP-only products never see the tunnel establish |
| Client profile the device can load | Certificates, credentials and server settings the Flexy or Cosy importer accepts | Tunnel stops at authentication or never starts |
| Hostname and wildcard address objects | Talk2M destinations are published as *.talk2m.com | Numeric-IP-only policy cannot express the outbound rule |
| Editable stateful egress rules | The device initiates outbound and replies ride the session table | Default-deny egress without the KB-0209 allowances blocks establishment |
| Routable tunnel interface | Replies to the Ewon LAN subnet need a return route into the tunnel | Tunnel shows connected but the PC behind the Ewon reaches nothing |
| Configurable server port | The client must reach the server through site egress filtering | A blocked port keeps the client offline; TCP 443 is the fallback listener |
Addressing decides whether traffic flows #
A tunnel that is up proves the secure session, not reachability. Four things must then agree: the PC behind the Ewon must send corporate-bound packets to the Ewon, the corporate firewall must hold a return route for the Ewon LAN subnet pointing into the tunnel, policy on both ends must permit the traffic, and the two subnets must not overlap. Overlap is the one you settle at design time, and it is pure arithmetic.
Worked example, with numbers to swap for your own:
- Ewon LAN subnet: 192.168.137.0/24. A /24 holds 2^(32-24) = 2^8 = 256 addresses, 192.168.137.0 through 192.168.137.255.
- Corporate network: 10.4.0.0/16. A /16 holds 2^(32-16) = 2^16 = 65,536 addresses, 10.4.0.0 through 10.4.255.255.
- Overlap test: RFC 1918 reserves 10.0.0.0/8, 172.16.0.0/12 and 192.168.0.0/16 as private blocks that do not intersect. Your two subnets sit in different blocks, so they share no address and the tunnel can route in both directions.
- The failing case: a corporate flat network of 192.168.0.0/16 spans 192.168.0.0 through 192.168.255.255, which contains the Ewon's entire range. No firewall rule repairs that; renumber the Ewon side to 172.30.7.0/24, which is 256 addresses inside the 172.16.0.0/12 block, before configuring anything.
- The firewall work that falls out of the numbers: one return route for the Ewon subnet into the tunnel, and one policy from that subnet to the corporate destinations.
Bring-up order #
- Prove outbound first: from the Ewon, confirm name resolution and that the session to the server, or to Talk2M, is permitted. Doing this before touching VPN settings separates filtering faults from profile faults.
- Bring the tunnel up and read both logs: the Ewon connection log and the firewall's server log tell you whether a failure is name resolution, denied egress, authentication or a certificate profile mismatch.
- Add the return route and policy, then test by IP address from the PC to a corporate device, so name resolution stays out of the result.
- Test names only after IP routing works.
The decision for each case #
- Talk2M only: buy on filtering, not on VPN termination. Any stateful firewall with alphanumeric hostname and wildcard address objects passes; you configure the documented outbound allowances and nothing else.
- Ewon client, firewall server: shortlist only products with an OpenVPN server role, and match the profile the Ewon loads against that server before ordering. pfSense with its OpenVPN server is a documented endpoint, and Anybus Defender is the purpose-built server for Ewon networks. Reject any product whose datasheet lists IPsec, PPTP or L2TP alone.
- Many sites into one head end: the documented scaling path is Anybus Defender as the OpenVPN server with Flexy and Cosy+ clients, which keeps one certificate and profile discipline across every site.
If you are weighing the protocol itself rather than the product, the trade-offs are laid out in selecting OpenVPN versus IPsec for industrial PLC remote access.
Questions asked
Will a firewall with only IPsec support work with an Ewon router?
No. The Ewon builds its tunnel with OpenVPN, so an IPsec-only firewall cannot terminate it. Some firewalls bundle several protocols, so check the feature list for an OpenVPN server role specifically, because that is the role the Ewon connects to as a client. PPTP and L2TP are equally out.
Does the corporate firewall need any VPN feature for Talk2M access?
No. Talk2M sessions are initiated by the Ewon and travel outbound, so a stateful firewall passes the return traffic on its own session table. You only add configuration when outbound traffic is filtered, and even then the rule set is the destinations and ports in KB-0209, with a wildcard object because the destinations are published by name rather than as fixed addresses.
Can pfSense act as the VPN server for Ewon devices?
Yes. HMS Networks publishes a setup guide that configures pfSense as an OpenVPN server in bridged mode and walks through connecting Ewon devices to it. Enable the OpenVPN server, issue or import the certificates the Ewon client will load, and plan the bridge against your addressing before you commit.
How many ports must stay open at the corporate edge for the direct tunnel?
One. In Ewon-client/firewall-server mode the Ewon initiates, so the only listening exposure is the OpenVPN server's port on the firewall's public side. Plan for one UDP or TCP port, and make it TCP 443 where site egress filtering is strict, since that port is the conventional fallback that filters rarely block.
Is a firewall with an OpenVPN client role enough?
No, not for this mode. The Ewon initiates the connection, so the corporate end has to accept it as a server. A firewall's OpenVPN client role belongs to site-to-site links between two firewalls you control; the Ewon's outbound-only design expects to dial in, not to be dialed.