How-to
Installing Process Historian 2013 Update 5 with KB2756195
Short answer
KB2756195 comes inside the Process Historian 2013 Update 5 package: extracting the archive creates a dedicated hotfix subfolder, and you run that hotfix manually before the update only when it is not already installed, so no Microsoft support contact is needed. The readme's Updates 1 to 4 line lists the accepted starting versions, so an installation at the Update 3 level goes straight to Update 5.
On this page
- Is the KB2756195 hotfix included in the Update 5 download?
- What do I record before touching the server?
- Do I have to install Updates 1, 2, 3 and 4 before Update 5?
- How do I run the hotfix and Update 5 in the right order?
- What should the installed-programs list show afterwards?
- Is it a problem when setup shows a different KB number?
- Can Update 5 go on a Windows 7 machine?
- What do I check first when tag data stops arriving after the update?
- Questions asked
KB2756195 ships inside the Process Historian 2013 Update 5 package, so you never have to request it from Microsoft. Extract the self-extracting Update 5 archive, open the _Microsoft_Hotfix_KB2756195 subfolder it creates, and run that hotfix manually before the update only if it is not already installed. The readme line naming Updates 1 to 4 is the list of starting versions Update 5 accepts, not a chain you must climb: a historian already at the Update 3 level goes straight to Update 5. The steps below cover a SIMATIC PCS 7 V8.0 SP1 server on Windows Server 2008 R2 Standard and fit one maintenance window with the historian stopped.
Is the KB2756195 hotfix included in the Update 5 download? #
Yes. Extracting the Update 5 self-extracting archive creates a subfolder named _Microsoft_Hotfix_KB2756195, and the readme carries the hotfix as its own installation step, executed from the package before the update itself.
That settles the Microsoft question: there is nothing to request and no support case to open, because the vendor ships the hotfix on the update media. What the media does not do is run it for you. The readme words the step as a separate instruction ahead of the update, so treat it as a manual run, in first position, whenever the server lacks it.
What do I record before touching the server? #
Record four facts from the server before anything is installed: the historian product name, its complete version string, the PCS 7 service-pack level and the operating system, because these entries are the only evidence you can compare against afterwards.
Open the installed-programs list and copy the historian's entry exactly as Windows shows it, because the update decision is a string comparison, not an impression. A baseline from a real PCS 7 V8.0 SP1 server reads:
- Product name: SIMATIC Process Historian Server 2013
- Version: K01.00.01.03_01.11.00.02
- Release: V8.0.1.3
- Platform: SIMATIC PCS 7 V8.0 SP1, with SIMATIC PCS 7 Tools at K08.00.01.00_01.14.00.01
- Operating system: Windows Server 2008 R2 Standard
Transcribe or photograph the whole block, including the Automation License Manager line, and note which Windows updates are already installed; both lists are what you compare against when the update is done.
Do I have to install Updates 1, 2, 3 and 4 before Update 5? #
No. Read the readme's Updates 1 to 4 line as the list of starting versions Update 5 accepts: Process Historian 2013 with any one of those update levels, so a server already carrying one earlier update goes straight to Update 5.
The sentence is genuinely ambiguous, so decide it from what the package accepts rather than from its punctuation. A missing standalone Update 4 download proves nothing about Update 4 being embedded or cumulative, and you do not need that question answered at all.
Worked example, using the baseline above: the release reads 8.0.1.3, so its trailing digit sits at 3, and the Update 5 package is designated K8.0.1.5, the same digit at 5, so one installation gains two update levels. The entry is therefore an Update 3-level installation, one of the accepted starting points. Decision: match the full string K01.00.01.03_01.11.00.02 against the readme list, confirm it is there, and install Update 5 directly, with no hunt for Update 4.
How do I run the hotfix and Update 5 in the right order? #
Stop the historian completely and back up first, then extract, run the hotfix if it is missing, and only then start the update, in that fixed order.
The vendor's Process Historian readme, as published with the 2020 SP2 Update 5 package, documents the two preparation rules its updates expect, and they hold for the 2013 line: the historian completely shut down for the update, existing data backed up before upgrading. With the backup verified readable and the server quiet, run the sequence:
- Back up the historian's existing data and confirm the backup is readable before the window opens.
- Shut down the Process Historian completely, server side, not just the client views.
- Place the Update 5 self-extracting archive in a folder on the server and start the extraction.
- Check whether KB2756195 appears among the installed Windows updates. If it does, skip ahead; if it does not, open
_Microsoft_Hotfix_KB2756195and execute the hotfix file inside, as the readme instructs from the extracted package. - Run the Update 5 setup, package designation K8.0.1.5; the Setup program guides the installation.
- Start the historian, reopen the installed-programs list and move to the checks below.
What should the installed-programs list show afterwards? #
The historian entry must have moved off the recorded baseline: with Update 5 designated K8.0.1.5, expect the release to read at the 8.0.1.5 level where the baseline showed its Update 3 digit, and the version string to change with it.
If the entry still shows the old strings after a restart, the update did not land; rerun the setup instead of assuming a display lag. Then prove the write path, not just the version: open a known tag in a trend and confirm the value and its timestamp are current, and watch a few minutes for fresh values. A changed version with a flat trend means the installation succeeded and the data path did not, so continue with the last section.
Is it a problem when setup shows a different KB number? #
No, provided you verified KB2756195 beforehand: one reported installation completed with a different KB number on screen, and the operator's reading was that the required hotfix was already present, so the check belongs before the run, not after.
Treat that report as a case, not a rule, because a differently numbered hotfix does not stand in for KB2756195. Your protection is the check in step 4: when the number was confirmed on the server before the window, whatever the setup displays later does not change the outcome. If it was not confirmed, do not reason from the screen at all; open the installed-updates list and look.
Can Update 5 go on a Windows 7 machine? #
No. The PCS 7 release information states that Process Historian is not released for Windows 7, so an engineering or IPC workstation running that operating system stays out of scope for this update regardless of edition.
Update 5 does not change that release list. Decision: the historian server stays on the Windows Server line, Windows Server 2008 R2 Standard for the baseline above, and no Windows 7 machine is part of this update.
What do I check first when tag data stops arriving after the update? #
Check the path from the source connection to the archive in order, starting with the tag connection, because an updated historian that runs but stores nothing has a data-flow fault, not an installation fault.
The archive comes up with the historian service, so when a trend is flat, walk the flow from the source: is the connection to the source system alive, are the tags actually exported to the historian, is the archive receiving them. If your values come from WinCC, follow the trace the article on why WinCC tag data never reaches Process Historian 2014 walks, from tag export to archive import; rule that path out before touching the freshly updated database.
Questions asked
Where do I get the Process Historian 2013 Update 5 download?
From the vendor's support portal: entry 92075334 carries the downloadable Update 5 for Process Historian 2013 and Information Server 2013 as a self-extracting archive. Download it into a folder on the server, start the extraction there, and keep the extracted tree until the update is verified, because the hotfix subfolder lives inside it.
How do I confirm KB2756195 is already installed before I start?
Open the installed-updates view under Programs in Control Panel on the server and look for the KB number. If it is listed, skip the hotfix step entirely; if it is absent, run the installer from the extracted hotfix subfolder before Update 5. The check takes a minute and settles the question before the maintenance window rather than during it.
Do earlier Process Historian 2013 updates ship their hotfix the same way?
One reported Update 3 installation found its Microsoft hotfix inside that package too, with the same manual run after extraction and before the update. The pattern holds across the 2013 update line: after extracting any of them, look for the hotfix subfolder and treat its installation as your own separate step.