Explainer
Why a 16K AVEVA Edge runtime license does not set Thin Client count
Short answer
The 16K figure in an AVEVA Edge runtime license is the tag-database ceiling, not a Thin Client count. Any license includes one concurrent Thin Client and the rest are separate line items — 99 more on the quote for a 100-client requirement — and whether one runtime actually carries that load is proven by a stepped load test of the real application, not by the tag tier.
On this page
- What the tag tier caps and what it leaves open
- Ask for the licensing answer in a form you can propose
- Why the same clients load the server differently
- Worked example: 100 concurrent Thin Clients on one runtime
- What sets the real ceiling: hardware, OS and network
- The load test that decides one server or several
- One runtime or several: the architecture decision
- Questions asked
A 16K AVEVA Edge runtime license caps exactly one thing: the runtime tag database. It says nothing about how many Thin Client sessions that runtime may host, because the concurrent Thin Client count is a separate licensed item — the vendor's introduction document for AVEVA Edge 2023 R2 states that any license supports at least one concurrent Thin Client, with additional clients as a separate purchase. Whether a single runtime can carry 100 sessions is a third question, settled only by a stepped load test of the real application. What follows is the licensing arithmetic, the request to send your distributor, and the test that decides one server or several.
What the tag tier caps and what it leaves open #
That tag figure is the ceiling of the runtime tag database and nothing else. AVEVA Edge licenses do not restrict features — the vendor's licensing pages state that all main features are supported in every license — so the tiers differ by tag count, not by capability, and moving up a tier buys no client capacity. The concurrent Thin Client count travels as its own item: beyond the session included with any license, every concurrent client is a purchased line item, and the count for your exact SKU has to come back in writing. Four open questions, four owners:
- The default concurrent count for the SKU: the licensing terms, confirmed in writing by the local AVEVA distributor.
- Whether the target is reachable on one runtime, and how: the distributor's quote.
- The licensing model, per client or bundle: the quote's line items.
- The performance ceiling: your own measured load test, in a later section.
Do not fill the first three lines from memory of older versions or other editions.
Ask for the licensing answer in a form you can propose #
Route the licensing questions to the local AVEVA distributor with the application description attached, because the distributor quotes your region and ties every answer to a named SKU. Send one package:
- The exact product and edition as the requirement names them: AVEVA Edge SCADA, Runtime license, 16K tags.
- The target, stated as concurrent sessions all connected at the same time — not named users. The concurrent-versus-named distinction is the same one that governs historian client concurrent licenses on one RDS server when one host serves many sessions.
- The default concurrent Thin Client count included in that license.
- Whether the target is licensable on a single runtime, and whether additional clients are sold per client or in bundles.
- Any documented system or performance limits for the Thin Client type.
- The workload paragraph from the next section.
Check before moving on: you hold a written reply that names the SKU and states a count, and a quote whose client line items add up to it. If the distributor answers that the target needs a different architecture, treat that as a design input for the final section, not as a refusal.
Why the same clients load the server differently #
In a Thin Client design the client is mainly a display. Screen logic, scripting and tag access execute on the server, so server load grows with the number of sessions multiplied by what each session does. A single dashboard watched by everyone with data-only requests is a light load; dozens of screens, screen-level scripting and frequent operator interaction make a heavy one. Classify the application before sizing anything:
- Read-only, one screen, shared data: the lowest per-session cost — measure CPU and RAM per added client.
- Many distinct screens open at once: each session holds its own screen state — measure memory per session.
- Scripts running on screen open or on tag change: execution multiplies by sessions — measure script time under load.
- Frequent operator writes and commands: extra write traffic and interaction handling — measure response to a button press.
Write the classification down as one paragraph — how many screens each client type opens, whether they write, which scripts run per session — and attach it to the distributor request. That paragraph, not the tag tier, tells the distributor and your test engineer what kind of load this is.
Worked example: 100 concurrent Thin Clients on one runtime #
Take the requirement as it arrives — an AVEVA Edge SCADA runtime license and a customer who wants every client connected at once — and work the licensing side down to a number. The inputs, each with its source:
- Required concurrent Thin Clients: 100 — the customer requirement.
- Concurrent Thin Clients included with any license: 1 — the vendor's introduction document for AVEVA Edge 2023 R2.
- Runtime tag ceiling: 16K tags — the SKU name; it does not enter the arithmetic.
The rule in words: the additional concurrent entitlements you must buy equal the required concurrent clients minus the clients the license already includes. Tag count appears nowhere in that rule.
The arithmetic: 100 - 1 = 99.
Result: the quote must carry 99 additional concurrent Thin Client entitlements against the named runtime SKU.
Decision: if the written reply confirms that one runtime may host the full count and the quote carries those 99 line items, accept the quote and run the load test on the license that will ship. If the distributor caps a single runtime below the requirement, stop sizing one server and split the sessions across several runtimes — no hardware will get past a licensing cap.
What sets the real ceiling: hardware, OS and network #
None of these limits can be read off the license. Take them from the AVEVA Edge documentation for your version and from the terms of the operating system you choose:
- Server CPU and RAM: the headroom at the full session count on top of I/O drivers, alarms and any logging already on the box — measured, not read from a datasheet.
- Operating system: whether the edition allows the connection count you need — the documented system requirements for your version and the OS vendor's terms.
- Network: bandwidth and latency from the farthest client site to the server — measured at that client, not across the server room.
- Shared load: the driver polling, alarms and logging the runtime already runs.
The baseline rule: record CPU and memory on the server with the full project running and zero Thin Clients connected, because every later reading subtracts this number.
The load test that decides one server or several #
Deploy the real project — every screen, script, driver and alarm — on hardware identical to the proposed server, with the license that will ship.
- Record CPU, memory and screen response with zero Thin Clients connected.
- Connect clients in steps of 10, each running the scripted operator workload from the classification, not an idle screen.
- At every step record CPU, memory, network throughput, screen-open time and command response time. The per-client cost is the reading at N clients minus the zero-client reading, divided by N; the projection to the target count is the baseline plus that cost multiplied by the target count.
- Hold the full count through one alarm burst and one burst of operator writes, and confirm alarms and tag values still update on time on every client.
- Confirm the runtime accepts the last connection under the license you hold; a refusal inside the entitled count means the installed license and the quote disagree, and no hardware change fixes that.
Pass criteria: CPU and memory stay inside the margin agreed with the customer, the farthest client meets its response-time target, and driver polling has not degraded against the first-step baseline. A passed test with margin is the only evidence that one server carries the load; the tag tier never was.
One runtime or several: the architecture decision #
Split when the licensing answer caps a single runtime below the requirement, or when the test shows a wall before the last step. Both layouts can work, so choose by risk:
- A single runtime carrying every session: simplest to maintain, one tag database, but its failure drops every client at once. Choose it only if the load test passes with margin and the license allows the count.
- Several runtimes, or a separated display tier: divides the sessions and isolates control-side I/O from viewer load. Choose it when the workload is interactive or heavily scripted, or when the requirement exceeds a licensed or measured limit.
If the runtime also drives process I/O, a viewer-load spike must never slow the polling the process depends on — that is the failure the split protects against. And if most of the users only watch, license Thin Clients for the operators who actually write and serve the viewers from a read-only path: concurrent RDP sessions to the runtime machine are one option, set up as described in enabling multiple concurrent RDP sessions for industrial HMI access. Whether a thin client model suits the site at all is worked through in thick client or thin client HMI for a control system upgrade. Final check: the proposal names one layout and lists the client line items that support it.
Questions asked
If operators work in shifts, does every shift need its own Thin Client license?
No. A concurrent entitlement is held by an open session, not by a named person, so a single workstation handed from shift to shift consumes a single entitlement. The count to license is the largest number of sessions open at the same time across the site, which is why the requirement is written as concurrent sessions rather than per user.
The test machine refused a session below the licensed count. Is the server undersized?
Look at the installed license first. Connection acceptance inside the entitled count is governed by the license on that machine, so compare it with the quote and correct it through the vendor's documented activation steps for the installed license. A genuinely undersized server shows up earlier as slow screens and degraded polling in the stepped test, which is exactly what that test exists to catch.
Does buying a larger tag tier add any Thin Client capacity?
No. Tag tiers size the runtime tag database, every tier carries the same feature set, and client entitlements are counted separately. Money spent moving up a tier buys database space for the application, not sessions for operators. If the application later outgrows its tier, the tag database is what blocks the project, never the client count.
Should view-only users be licensed as Thin Clients?
Every open Thin Client session consumes an entitlement, whatever it displays. If most users only watch, license the operators who actually write and serve the viewers from a separate read-only path such as concurrent RDP sessions. That split can shrink the client line items on the quote substantially, and the load test then runs against the interactive count only.