Short answer

On a thin client, the installer's low-memory warning is a free-space failure at the temporary folder, not a shortage of the 2 GB of installed RAM. Sign in as Administrator, disable File Based Write Filter Control, set the RAM Disk size down for the install window, and point the Windows temp directory at a thumb drive with room for the payload; install, then restore the filter and the original settings.

On this page
  1. Why does an installer report low memory on a thin client with 2 GB of RAM?
  2. What does the write filter do to a software installation?
  3. Do I need an Administrator account to install software on a thin client?
  4. How do I resize the RAM disk before running the installer?
  5. Where should the temp directory point during the install?
  6. How much temp space does an installer actually need?
  7. In what order do I make the changes and retry?
  8. How do I confirm the installation survived the reboot?
  9. What if the installer still reports low memory?
  10. Questions asked

A thin client that reports low memory during a software install is almost never out of RAM: the installer has run out of space at its temporary folder. The reported case was a Windows Embedded thin client being loaded with Ignition Panel Edition for backup duty, where the prompt demanded a reboot on every attempt and the install only went through once the write filter was off, the RAM disk resized, and the temp directory sitting on a thumb drive. Running clients day to day with a local runtime reserved for server-down backup is the split described in the thick client or thin client HMI comparison; the sequence below gets that backup runtime onto a locked-down image.

Why does an installer report low memory on a thin client with 2 GB of RAM? #

The warning is about free space at the installer's temporary folder, not the 2 GB of installed RAM: the image points the temp path at a RAM disk carved from memory, and a payload bigger than that disk fails the space check before setup writes anything.

Read the number in the prompt as a space gauge aimed at one folder. An installer extracts its archive to the Windows temporary location before it writes program files, and on these images that location sits on a RAM disk. The administrator guides the vendor publishes for its Windows Embedded Standard 7 and Windows 10 IoT thin clients both describe the RAM Disk as a volatile memory space used for temporary data storage, with a configurable size. The reported unit was a Dell Wyse C90LEW bought with 4 GB of flash and 2 GB of RAM, and the prompt returned on every attempt because a reboot rebuilds the RAM disk at the same size. Nothing about that hardware is short; the temp target is.

What does the write filter do to a software installation? #

The filter keeps the system volume read-only, so an installer's writes either vanish at the next reboot or fail outright; File Based Write Filter on Windows Embedded 7 images and the Unified Write Filter on Windows 10 IoT both have to be off while setup runs.

File Based Write Filter Control is the applet these Windows Embedded images ship with. It discards writes to the protected volume, which is what keeps a kiosk profile clean and also what makes an installed program disappear or an installer's commit step fail. Microsoft's successor filter, the Unified Write Filter, does the same job on Windows 10 IoT Enterprise, and the same off-while-installing rule applies. Leave the filter off for the whole install window and switch it back on afterwards; on a full industrial PC the equivalent job is described in configuring UWF write protection on a Windows 10 IPC.

Do I need an Administrator account to install software on a thin client? #

Yes: the user profile a thin client boots into is deliberately restricted and cannot change the filter, the RAM disk, or the temp variables, so sign in as Administrator and make every change from that one session.

The boot profile on a managed thin client is a kiosk user on purpose: no filter control, no disk tools, and no environment variables it can alter. An install attempted from that profile fails in ways that look like damaged media or a defective unit. The documented procedures for these images run from the Administrator login, and the reported one did the same: account first, then filter, then RAM disk, then temp.

How do I resize the RAM disk before running the installer? #

The model's administrator guide documents a RAM Disk page with a size box: record the value shown, set the size down, apply, and restart so the smaller disk exists before the installer runs.

The guides for both the Windows Embedded Standard 7 and the Windows 10 IoT models describe the same page: a RAM Disk entry in the navigation and a box where you type or select the size. The number to restore later is whatever the box shows before you touch it, so write it down first. Shrinking the disk for the install window frees RAM and takes the volatile volume out of the temp equation. The disk is rebuilt from RAM at every boot, so the new size only exists after the restart.

Where should the temp directory point during the install? #

At a writable drive that is present for the whole setup: plug in a thumb drive first, format it NTFS, and point the TEMP and TMP environment variables for the Administrator session at a folder on it, for example one named install_temp on the drive's root.

Windows reads TEMP and TMP for every process it launches, installers included, and a user variable set for the Administrator session overrides the system default for that session's installs. Set both variables to the same folder, through the Environment Variables dialog in advanced system settings. Keep the format NTFS: a FAT32 volume refuses any single file larger than 4 GB minus one byte, which turns a large payload into a second, different failure. Once the install is done, the variables go back to their original paths before the drive comes out.

How much temp space does an installer actually need? #

Plan the temp location at twice the installer download's size: a 250 MB setup file needs roughly 500 MB of free temp space, because the archive is extracted and working copies are made before anything lands in Program Files.

The 256 MB and 500 MB in this example are illustrative values, not the reported unit's settings; read the real size from the RAM Disk box before you plan.

The arithmetic decides it. Take a 2 GB unit, 2048 MB. Suppose the image and running session hold 1024 MB and the box reads 256 MB. The installer's check looks only at the temp path, so it sees 256 MB against a 500 MB need and comes up 244 MB short - the low-memory prompt with a reboot request attached, on a machine with 2048 - 1024 = 1024 MB of RAM nominally idle. Move TEMP and TMP to a thumb drive with 4 GB free, 4096 MB, and the same installer has 4096 - 500 = 3596 MB of margin and finishes. Give the temp location at least twice the download's size and keep the RAM disk out of the install entirely.

In what order do I make the changes and retry? #

Work through account, filter, RAM disk, temp path, install, restore, in that order, because each step removes a constraint the next one depends on, and change nothing else until you have seen which step clears the prompt.

  1. Sign in as Administrator.
  2. Open File Based Write Filter Control and disable the filter; on a Windows 10 IoT image, use the Unified Write Filter controls instead.
  3. Record the value in the RAM Disk size box, then set the size down on the guide's RAM Disk page.
  4. Plug in the thumb drive, format it NTFS, and point TEMP and TMP at a folder on it for the Administrator session.
  5. Restart if the filter or RAM Disk tool requires it, and re-check that both settings took.
  6. Run the installer; it should extract and finish without the low-memory prompt.
  7. Point TEMP and TMP back, restore the RAM Disk size, re-enable the filter, restart, and launch the software once more.

The vendor's own knowledge base documents this sequence for these images; the original Wyse article carried the number 10687, and the current Dell support pages for the model's administrator guides describe the same filter and RAM Disk steps.

How do I confirm the installation survived the reboot? #

Restart with the write filter back on and launch the software from the normal user profile: everything the installer wrote while the filter was off is committed to flash, so a clean start with the filter on proves the install persisted.

Then test the role the unit was bought for. Take the SCADA server down by its approved method inside a planned window - never by cutting power to prove a failure - confirm the local runtime serves the operator screens, and bring the server back. One limit to plan around: with the filter on, anything the backup runtime writes to the protected volume, trend files and local logs included, is discarded at the next restart. If backup mode must keep data on the unit, that output needs the filter's documented exclusion list or a filter-off window of its own.

What if the installer still reports low memory? #

Change one setting at a time, because a restart rebuilds the RAM disk by design, and a setting you thought was applied may not have survived it, so verify each state after every reboot before touching the next one.

Watch the temp drive's free space while setup runs, and confirm after each restart that the filter is off and the RAM Disk size is the one you set - volatile state is exactly what a reboot clears. On a managed fleet, the device-management profile that pushes configuration and firmware can push the original settings back too, so take the unit out of that profile for the install window. An installer that fails on one Windows machine and runs on another is an environment difference more often than a hardware fault, the same logic as in why commissioning software fails on one Windows PC but not another.

If the prompt survives every verified setting, the unit has hit a real resource floor: capture the exact message with the model, memory and flash configuration, and take it to the software vendor's support channel. When the finding is that the appliance cannot be expanded - thin clients ship as fixed configurations - the backup runtime belongs instead on an industrial mini PC sized to the runtime's documented minimums.

Questions asked

Does software installed while the write filter is off stay installed after it is back on?

Yes. Every file and registry entry the installer wrote while the filter was off is committed to the flash volume, and switching the filter back on does not remove it; it only makes the volume read-only again. The catch is maintenance: a patch or update installed later will not survive a reboot until you repeat the same window with the filter disabled, so schedule that window for every update.

What RAM Disk size should the unit keep afterwards?

Restore the value that was in the RAM Disk size box before you changed it, and raise it only if the client role genuinely runs short in daily use. Every megabyte of RAM disk is a megabyte of installed memory the runtime can never touch, so an oversized disk quietly starves the application you just installed. Read the original value from the box, not from a general recommendation.

Can I leave the temp directory on the thumb drive permanently?

No. Windows and many services expect a temp path that is always present; if the drive is unplugged, fails, or mounts under a different letter after a reboot, installers and applications that write to temp fail again. Use the thumb drive for the install window only, then point TEMP and TMP back at the internal disk before removing the drive.

Why does the error ask for a reboot instead of failing outright?

Windows installers hold handles open and schedule file operations while they extract, so when the space check or a write fails, they roll back and request a restart to clear the locks. The reboot clears the locks but not the constraint: the RAM disk rebuilds at the same size and the temp path is unchanged, so the identical prompt returns on the next attempt.

Would adding memory or a bigger flash module fix the error?

No. Thin clients are bought as fixed appliances, and the failure was never the installed memory itself; it was free space at the temporary folder the installer checks, which more RAM does not enlarge. Only moving or resizing that folder does. If the appliance still cannot run the software after the settings are correct, the unit is underspecified for the role and should be replaced.

Keep reading

  • Comparison

    Thick client or thin client HMI for a control system upgrade

    A thin-client HMI does not remove processor, memory, disk and network load; it concentrates all of it in one server and one network, so one failure can blank every operator position. Choose thin clients only if the site can staff, back up and recover that server; otherwise refresh thick clients, where a failure costs one station. Virtualizing the Windows XP HMI is a transition, not a modernization.

    Remote access and virtualization

  • How-to

    P2V migration plan for an aging Windows machine controller

    Converter 6.3 does not support Windows 7 as the computer it installs on, which is what the openssl.exe startup failure and the Error 29190 SSL-key message are reporting. Stop installing on the failing controller: back it up, run the converter from a supported management computer, and convert the Windows 7 source only with a release whose supported lists cover it — otherwise rebuild on a supported system. Current 6.6 and 9.0 lists start at Windows Server 2012 and Windows 10.

    Remote access and virtualization

  • Troubleshooting

    Box PC disk imaging to USB fails in the boot environment

    USB Legacy in the BIOS serves the pre-boot firmware only; the DOS boot environment Ghost V7 runs from needs its own driver for the USB controller and the enclosure. Prove which environment can see the destination, then change the transfer path — a boot medium with storage support, a network destination, or the disk moved to a bench PC — instead of re-toggling BIOS settings.

    Operating systems on the plant floor