Historian Client Web follows the browser's first preferred language, but only among the translations the installed release and its classic or modern experience include; with no match it falls back to English. Set the language first in the browser and reload; if the release lacks it, the Web language pack comes through the distributor. The Historian Client Language Toolkit localizes Desktop only.

On this page
  1. How the Web client picks its language
  2. What your release actually includes
  3. Where the Language Toolkit applies
  4. Worked example: Italian first against the documented four-language set
  5. Checklist when the client stays in English
  6. The decision for each case
  7. Questions asked

Historian Client Web takes its interface language from the browser's preferred-language list: the client renders the first entry in that list that it has a translation for, and when nothing matches it stays in English. So an English screen is one of two faults — the browser's order is wrong, or the installed release and its experience (classic or modern) does not ship the language you asked for. The Historian Client Language Toolkit belongs to neither case, because it localizes Historian Client Desktop only. Fix the browser order first; when the release lacks the language, the Web language pack through your distributor is the route.

How the Web client picks its language #

The browser keeps an ordered list of preferred languages and sends it with every request. AVEVA documents this mechanism for Insight: to see French text, make French the first preferred language in the browser. Historian Client Web reads that order for each session and serves the first language it can.

In Chrome the list lives under Settings in the Languages area — Languages and Input Settings — where Add puts a new language into the list; it has to sit above the others to count as first. The equivalent list exists in every major browser under its own language settings.

The preference travels with the operator's browser session, so it holds whether the client is opened directly or after exposing a historian web client through a reverse proxy. Nothing on the server side picks the language.

What your release actually includes #

The browser setting is a selector, not a translator: it can only choose among the translations the installed release includes. Those sets differ by release and between the classic and modern experiences — one release's list is not another's, and the documentation for the modern look covers language-pack integration on its own.

Insight's documented set — English, French, Spanish and German — is a benchmark for the mechanism, not the on-premises Web client's list. Before promising any language, record the installed Historian release and which experience the session uses, then confirm the language against that exact combination.

Decision: listed for your release and experience — the browser order is the whole fix. Not listed — no browser change will produce it.

Where the Language Toolkit applies #

The Historian Client Language Toolkit localizes Historian Client Desktop. Installing it changes nothing in a browser session, because the Web client never reads Desktop's localization files. Web and Insight localization are separate resources, supplied through distributors.

Localization path Applies to Effect
Browser preferred-language order Historian Client Web Picks the first preferred language the installed release translates
Historian Client Language Toolkit Historian Client Desktop Localizes Desktop; the Web client never reads it
Web/Insight localization resources Web and Insight Separate language packs, supplied through distributors

Worked example: Italian first against the documented four-language set #

Inputs, each with its source:

  • Requested order from the operator's Chrome, Italian placed first with English as fallback: it-IT, it, en-US, en — the reader's own case.
  • Available set as documented for AVEVA Insight: en, fr, es, de — a benchmark, not the Web client's list.
  • Installed Historian Client Web release and experience: not recorded yet, so which translations it includes stays untested until you write it down.

Rule in words: the client walks the browser's list from the top and renders the first entry whose base language it has a translation for; if no entry matches, it renders English.

The walk, written out:

  1. it-IT — base language it. Is it in {en, fr, es, de}? No. Move down.
  2. it — base it. In the set? No. Move down.
  3. en-US — base en. In the set? Yes. Stop.

Result: the interface renders English from the third entry, with Italian sitting untouched at the top of the list.

Decision: if your release's Web translation list is the documented four, Italian cannot appear at any browser order — order the Web language pack through the distributor for that release, or keep those operators on Desktop, where the toolkit applies. If the installed release does list it, the same walk stops at entry 1: set Italian first once, reload, done. First match wins; zero matches means English.

Checklist when the client stays in English #

  1. Confirm the screen really is Historian Client Web in a browser — not Historian Client Desktop, not Insight. The three take different fixes.
  2. Write down the installed Historian release and whether the session is the classic or the modern experience.
  3. Put the wanted language first in the browser's preferred-language list (Chrome: Settings, Languages, Languages and Input Settings, Add, then first).
  4. Reload the client and read the interface text.
  5. If the order looks right and the text does not change, repeat once in a second browser profile.
  6. Still English — check the translation list for exactly that release and experience, and treat Insight's four as a benchmark only.
  7. Absent from the list — ask the distributor for the Web/Insight localization resources for that release; do not install the Language Toolkit as a Web fix.

The decision for each case #

  • The language is listed for your release and experience: fix the browser order and reload; that is the entire repair.
  • The language is not listed: browser work is finished — order the Web language pack for that release, or move those users to Desktop with the toolkit.
  • Someone proposes the toolkit for the Web client: decline; its scope is Desktop, and it has no path into a browser session.
  • You are quoting Insight's languages as the Web client's: stop at benchmark — the on-premises list is per release and experience, and only that list counts.

Questions asked

Does the Windows display language on the PC or the server matter?

No. The Web client runs in the browser and reads that browser's preferred-language list; the PC's Windows display language and the server's locale are not consulted. Only the browser profile the operator opens the client in decides, which is why the same URL can show different languages on two machines.

Why does one operator get the translated interface and another English?

Because the list is per browser profile. Each browser, and each profile inside it, keeps its own preferred-language order, and the client follows whatever that profile sends. A shared kiosk browser has a single list, so every user of that machine gets the same language until someone changes the list.

Can I set one language for every user from the server?

The preference is read in the browser, so the Historian server has no language setting to change. To standardize, preset the preferred-language order through your browser's enterprise policy where that policy set covers the language list; the Web client then follows it like any locally chosen setting.

Will a release upgrade change the available languages?

It can, in either direction. Translation sets differ by release and between the classic and modern experiences, so treat the language list as part of upgrade qualification: after any upgrade, or any switch between experiences, confirm the language still appears before you promise it to operators.

Keep reading

  • Explainer

    AVEVA Historian to PI replication version requirements

    Replication from AVEVA Historian to AVEVA PI needs the 2023 release of Historian or later and PI Web API v1.16.0 or later on the destination. The two version numbers never need to match, and there is no direct requirement on the PI Archive version. Historian-to-Historian replication instead requires the destination to be the same version or newer than the source.

    Edge computing and IIoT

  • Troubleshooting

    Diagnose a slow historian web client page load on the server

    Capture the load in the browser Network tab with the cache disabled and split each slow request into connection, TLS, waiting and download phases. When waiting for server response holds most of the time, the historian web services are waiting on the shared SQL Server host: cap Max server memory, check disk latency, then send support a redacted HAR. The timing split, not the total load time, decides the cause.

    Edge computing and IIoT

  • How-to

    Expose a historian web client through a reverse proxy

    Forward a port, mapping the client-facing port 8069 to the web client site on port 32569, whenever a host-and-port URL is acceptable; use a rewriting reverse proxy only when the URL must carry a path such as /hcweb, because the web client returns local URLs and redirects that plain forwarding does not rewrite.

    Edge computing and IIoT