Troubleshooting
Why MQTT Engine tags miss transmitted Sparkplug properties
Short answer
MQTT Transmission publishes a tag property in DBIRTH only when it is unfiltered and its value differs from the Ignition default, and MQTT Engine applies it only when its own filtered list permits. On the reported 4.0.20 modules, Convert UDTs blocks properties on UDT-derived tags; disable conversion, refresh the transmitter, and the properties land.
On this page
- Why don't transmitted Sparkplug properties appear on MQTT Engine tags?
- Is this the same problem as MQTT Engine's filtered namespaces?
- When does MQTT Transmission publish a property into DBIRTH?
- Why do properties reach DBIRTH but stop short of the Engine tags?
- Which tags keep their transmitted properties and which lose them?
- How do I test property propagation end to end?
- What do I check when properties still will not land?
- Questions asked
MQTT Engine drops transmitted Sparkplug tag properties for one of two reasons: the property never held a value that differs from the Ignition default, so MQTT Transmission suppressed it from BIRTH, or Convert UDTs was enabled on the transmitter, so the properties did not survive conversion to normal tags. The reported reproductions sit on MQTT Transmission 4.0.20 and MQTT Engine 4.0.20 with the default Sparkplug B namespace. Work the checks in order: confirm the value is non-default at the source, confirm the name is off both filtered lists, read DBIRTH, then turn off UDT conversion and refresh the transmitter.
Why don't transmitted Sparkplug properties appear on MQTT Engine tags? #
Two gates sit between a tag property configured at the edge and the same property on an auto-created Engine tag: MQTT Transmission publishes it only when it is unfiltered and its value differs from the Ignition default, and MQTT Engine applies it only when its own filtered list permits.
In the reported case the transmitter list had been trimmed to 23 properties, including opcItemPath, rawLow and tagGroup, a broker subscription showed those properties inside DBIRTH, and the tag browser still displayed only the Read Only property applied under the Engine's node. That combination localizes the fault: the publish gate passed, so the loss sits between the broker and the Engine's tag creation, not in the transmitter's list. Engine is designed to apply payload metadata to the tags it auto-creates — its remote tag provider documentation names engineering units, deadband and the low and high limits as attributes that arrive with the payload — so a missing property points to configuration or conversion, never to a missing feature.
Is this the same problem as MQTT Engine's filtered namespaces? #
No: the Filtered Namespaces setting decides which Sparkplug topics MQTT Engine turns into tags at all, while filtered properties decide which attributes ride onto the tags it creates, so a property can vanish from healthy tags even though every tag arrived in the namespace.
The two lists sit near each other under each module's advanced settings, which is why they get confused. They act at different stages: a filtered namespace removes the topic before any tag exists, while a filtered property strips one attribute from a tag that was created normally. Tags that exist and carry live values prove the namespace side is healthy, which leaves attribute handling as the only open question. That namespace feature has its own reversed deny-list logic, covered step by step in why MQTT Engine filtered namespaces works backwards.
When does MQTT Transmission publish a property into DBIRTH? #
MQTT Transmission publishes a tag property into the DBIRTH payload only when two conditions hold at once: the property is absent from the transmitter's Filtered Properties list, and its value differs from the default Ignition tag property value, a rule that covers custom properties as well.
That is the module's documented publish behavior, not a quirk observed once. Two consequences decide most tickets. A property left at its default — a history flag still false, a deadband untouched from installation day — is suppressed even though you removed its name from the list, because removing a name permits publication but never forces one. And the Engine keeps its own Filtered Properties list in its advanced settings, so a property has to clear both lists before it can reach an auto-created tag; the reported setup had done exactly that on both sides, which is why DBIRTH was full and suspicion moved downstream.
Why do properties reach DBIRTH but stop short of the Engine tags? #
On the 4.0.20 modules, the reported cause is Convert UDTs: with that transmitter option enabled, UDT members are converted to normal tags before publishing and the transmitted properties never land on the Engine tags, even though the same properties are visible in DBIRTH at the broker.
The transmitter option flattens UDT members into normal tags before publishing, and on the reported pairing the flattened members arrived on the Engine without their properties while the same properties sat in DBIRTH. Turning Convert UDTs off and refreshing the transmitter regenerated BIRTH with the UDT definitions included, and the properties propagated to the rebuilt instances.
Treat that as a binary choice on the reported builds: conversion enabled keeps flattened member tags but drops their properties; conversion disabled keeps the properties and the UDT structure, because definitions travel in BIRTH and Engine rebuilds each instance. Scope the finding to these module versions and retest after any upgrade. A property present in DBIRTH but absent from the tag is an Engine-side failure, so stop working the transmitter at that point.
Which tags keep their transmitted properties and which lose them? #
In the reported tests, plain tags without UDTs and UDTs published with their definitions intact kept every transmitted property, while members pushed through UDT conversion lost them, and the split followed the conversion option alone rather than the size or complexity of the definition.
A simple UDT definition and a single instance reproduced the loss, which made definition complexity look like a suspect, but nothing in the testing confirmed it — treat complexity as unproven and work the conversion option first. The table is the reported outcome set, not a specification for every module build.
| Tag arriving at the Engine | Transmitted properties on the created tag (reported) |
|---|---|
| Plain tag with no UDT | Applied |
| UDT instance, Convert UDTs off, definitions in BIRTH | Applied |
| UDT members published through Convert UDTs | Missing |
| Read Only property on any tag type | Applied |
The Read Only property is the control case: it landed on every tag even while the rest waited, which proves the BIRTH message itself was reaching the Engine intact.
How do I test property propagation end to end? #
A two-property probe proves the whole path in one refresh: set HistoryEnabled from False to True and HistoricalDeadband from 0.01 to 0.05, keep both names off the filtered lists on both modules, refresh the transmitter, and both properties should appear on the Engine tag.
The reported test did exactly that. Flipping HistoryEnabled moves a boolean off False, and moving HistoricalDeadband to 0.05 puts a number well away from the 0.01 the tag held before: 0.05 - 0.01 = 0.04. Either change alone clears the default-value gate, because that gate compares against the Ignition default, not against zero or against your previous setting.
Subscribe to DBIRTH first and confirm both names in the payload — that single check acquits Transmission, and whatever happens next belongs to the Engine. A bench with one plain tag and one single-member UDT isolates the whole path from production traffic; if you are standing up that kind of environment, building a unified namespace lab with Ignition and Sparkplug B lays out the broker, modules and namespace layout end to end.
What do I check when properties still will not land? #
Run the checks in order and stop at the first one that fails, because each step hands the problem to the next stage of the path: source value, both filtered lists, the BIRTH payload, the conversion setting, then the Engine tag itself.
- Check the value at the edge tag. A property still at its Ignition default is suppressed by the transmitter even when its name is off the list; change the value or accept that the property will not travel.
- Check both lists. The name must be absent from the transmitter's Filtered Properties list and from the Engine's matching list; either one alone blocks the attribute.
- Refresh the transmitter and subscribe to DBIRTH. A missing property ends the diagnosis on the transmission side; do not touch the Engine yet.
- Read the Engine tag. If DBIRTH carries the property and a UDT-derived tag lacks it, turn off Convert UDTs and refresh again; on the module pairing named earlier this is the confirmed trigger.
- Confirm the rebuilt tags. For UDT instances, check that the definitions arrived in BIRTH and that each required property now reads correctly in the tag browser.
- Escalate with evidence. If a plain tag still loses a confirmed non-default property, open a ticket with the module vendor and attach the edge tags and UDT definitions plus the complete filtered-property lists from both modules.
The decisions follow the same fork. A property at its default at the source: change the value or drop the requirement, because no list edit will publish it. A property missing from DBIRTH: fix the transmitter — value or filter list — and recheck. A property in DBIRTH but missing from a converted UDT tag: disable conversion, refresh and verify, accepting the UDT structure in exchange. Anything that still reproduces on a plain tag with every check green goes to the vendor with the attachments above.
Questions asked
Which Ignition and module versions does this behavior come from?
The reported pairing was Ignition Edge 8.1.33 running MQTT Transmission 4.0.20 on the publishing side, and Ignition Standard 8.1.32 running MQTT Engine 4.0.20 on the receiving side, both on the default Sparkplug B namespace. The Convert UDTs finding is documented against those module builds; treat it as version-scoped and retest after any module upgrade.
Do I need to restart the gateway after turning off UDT conversion?
No restart was needed in the reported case: unchecking Convert UDTs and refreshing the transmitter regenerated the BIRTH message, and the properties appeared on the Engine tags after that single refresh. Restart a gateway only when the vendor documentation asks for it after a configuration change; here the refresh alone was sufficient.
Does Device Level UDTs as Devices cause the missing properties?
It was enabled in the reported configuration and was never identified as the trigger. The behavior followed Convert UDTs alone: with conversion on, converted UDT members lost their properties, and with it off, UDT instances published with definitions in BIRTH kept them. Leave Device Level UDTs as Devices as your topology needs and change the conversion setting instead.
Why does only the Read Only property land on my Engine tags?
That was the reported symptom before the cause was found: every tag under the node picked up the Read Only property while the other transmitted properties waited. Its presence confirms the BIRTH message reaches the Engine intact, so it points the diagnosis at the default-value rule and the conversion setting rather than at connectivity.