How-to
Moving AVEVA Historian 2020 from 500 to 5000 licensed tags
Short answer
Yes, as a path: InTouch Unlimited Professional is documented with a 5,000-tag Historian capacity, so it fits a move from 500 tags once the AVEVA distributor confirms in writing that the entitlement covers the installed Historian 2020. Apply the confirmed license, then configure and prove collection of the additional tags separately — a bigger license never configures tags by itself.
On this page
- Can Historian 2020 run with an InTouch Unlimited license?
- How do I confirm the entitlement before changing anything?
- What does the licensed tag count actually limit?
- How do I apply the new license?
- How many tags fit in a 5,000-tag license?
- How do I prove the extra tags are collecting history?
- What if history is still missing after the license change?
- Questions asked
Yes — the path exists, and it is a licensing change, not a tag-count edit. AVEVA's product information lists InTouch Unlimited Professional with a 5,000-tag Historian capacity, which covers a move from 500 to 5,000 tags on paper. What decides it is written confirmation from your AVEVA distributor that the entitlement applies to your installed Historian 2020. Apply the confirmed license, then configure and prove collection of the additional tags separately — a larger license never configures anything by itself. This article walks the whole change: entitlement verification, license application, tag budget, and end-to-end proof.
Can Historian 2020 run with an InTouch Unlimited license? #
Yes, as the candidate path: AVEVA's product information for InTouch Unlimited Professional lists a 5,000-tag Historian capacity, which covers a 500-to-5,000 move on paper — but only a written distributor confirmation proves your entitlement covers the installed Historian 2020.
Licensing for combined InTouch and Historian deployments varies by version, bundle and commercial agreement, so the bundle name alone settles nothing about Historian rights. The authoritative source is your local AVEVA distributor or channel partner: they hold your exact product versions, current licenses and commercial terms, and can issue a contract-backed confirmation. Treat the request as a licensed-capacity change from 500 to 5,000 tags on the same Historian 2020 environment — never as a settings edit that expands capacity by itself.
How do I confirm the entitlement before changing anything? #
Get one written confirmation from your AVEVA distributor or channel partner that states three things: the entitlement applies to Historian 2020, its licensed tag count is 5,000, and the change leaves your other licensed components untouched.
Before that call, record the baseline so the confirmation has something to attach to: installed Historian and InTouch versions, the current license description, the current licensed tag count of 500, and the configured tag count in the application. Two checks deserve their own sentence in the confirmation:
- Version coverage. A statement that a newer release's license runs older software is version-specific, not universal; the check itself is laid out in AVEVA Historian 2023 R2 license backward compatibility explained.
- License model. If the move takes you between perpetual and Flex terms, the entitlement mechanics change with it — see AVEVA Historian Flex licensing and redundancy credits explained.
If the distributor cannot confirm Historian 2020 coverage in writing, stop there: an unconfirmed entitlement applied to a production historian is a worse position than the 500-tag ceiling you already understand.
What does the licensed tag count actually limit? #
The Historian license caps how many tags may store history — 500 today, 5,000 after the change — and nothing else: it is a capacity ceiling, not a fault in any tag, binding or connection.
AVEVA licenses Historian by maximum tag count: the tags you configure for storage must total no more than the licensed figure, and that figure is the governing number in every diagnostic that follows. Keep the layers separate when an operator reports missing history. The visible symptom is unavailable data; the cause can be the entitlement ceiling, a tag that is not configured for collection, or a connection fault. A larger license fixes only the first. It does not correct an invalid tag name, a failed binding or an acquisition problem, so decide which layer failed before spending the license change on it.
How do I apply the new license? #
Run it as a licensed-capacity change under your change-control process: back up the current license and configuration, apply the entitlement media the distributor supplies, restart only what the procedure requires, then confirm the reported capacity reads 5,000.
- Record the baseline: Historian and InTouch versions, current license description, licensed tag count, configured tag count.
- Back up the current license file and the Historian configuration.
- Apply the new entitlement using the licensing procedure supplied with it, inside your change window.
- Restart or reload components only where that procedure requires it.
- Check the Historian license status; the licensed tag count must report 5,000, not the old 500.
- Review the status of every other licensed component before returning the system to service.
Apply only the entitlement issued for this site. License media or keys taken from another installation are a licensing violation and unverifiable — the reported capacity would mean nothing.
How many tags fit in a 5,000-tag license? #
Everything you configure must total at most 5,000, counted as configured Historian tags, not as controllers or servers — and plan to stay below it, because zero headroom turns the next added tag into a license violation.
Worked example, with illustrative counts you replace with your own:
- Existing configured tags: 486.
- Expansion scope: 4,650 new points.
- Required total: 486 + 4,650 = 5,136 tags.
- Overrun against the license: 5,136 − 5,000 = 136 tags.
Those 136 tags are the decision. Either take them out of scope — logging minute averages where you planned raw intermediates frees more than 136 points in most expansions — or step up to the next Historian tag tier before the project starts. If you descope, do not land exactly on 5,000: at 4,750 configured tags you hold 5,000 − 4,750 = 250 tags of headroom, 250 ÷ 5,000 = 5%, which is the minimum margin worth carrying into a running plant.
How do I prove the extra tags are collecting history? #
Confirm three things after the license reports 5,000: representative tags beyond the old 500 ceiling are configured for collection, Historian diagnostics show no license or acquisition errors, and each checked tag has samples timestamped after the change.
- Pick a sample spread across the new tag set, including tags that previously sat beyond the 500-tag ceiling.
- Verify each one is defined, configured for historical collection, and pointed at the expected controller or application source.
- Read Historian diagnostics for licensing, acquisition and communication errors. A historian running in demo mode with a license tag violation is an entitlement symptom, traced in Historian secondary in demo mode and license tag violation.
- Confirm new samples — a known tag, a plausible value, a timestamp after the cutover. An accepted license with no new stored data proves nothing about acquisition.
- Have the operator confirm the values in the display or client that consumes them.
What if history is still missing after the license change? #
Then the license was not the fault, or not the whole fault: trace one failing tag from the display binding to the application tag to the source value to its collection configuration, in that order, before touching licensing again.
Each stop answers a different question — is the binding valid, does the tag exist, does the source hold a live value, is collection configured — and the first stop that fails names the fix. The license change is finished and should not be revisited while the count reports 5,000. For the collection-side fault, the full trace is the one in Historian trend empty: PLC tag collection troubleshooting; if diagnostics instead show the configured count over the licensed figure, you are back to entitlement, and that goes to the distributor with your baseline record.
Questions asked
Will operators see an error when the licensed tag count is exceeded?
Not on the display. Historian logs a license tag violation to its diagnostics while live values can still read normally at the HMI, so an exceeded license looks like selective missing history rather than an alarm. Check license status and diagnostics together: if the configured count sits over the licensed figure, that violation is the cause, and the fix is entitlement, not tag configuration.
Is the Historian tag limit the same as the InTouch tag limit?
No, they are separate limits. AVEVA's InTouch documentation states an application is bounded by available memory, with testing cited up to 300,000 tag handles. The Historian license is counted in licensed tags instead. Raising one does not raise the other, and neither figure is a performance guarantee at those counts.
Can I configure the new tags before the license arrives?
You can build the tag definitions and collection configuration in advance, but hold the cutover. Tags configured beyond the licensed count do not store history, so you would collect nothing and read a license violation. Sequence it as entitlement first, license applied and reporting 5,000, then tags brought into collection.
What record should I keep of the license change?
Keep the written distributor confirmation, the before and after license files, the reported tag count before and after, and your verification evidence: sample tags, values, timestamps and diagnostic results. If a later audit or support case questions the entitlement or the capacity, that file answers it without a second discovery exercise.