Comparison
One central gateway or Edge per building across ten subnets
Short answer
A second network card gives each building PC another attachment, not a route, so a central gateway still needs routed paths to every building subnet. For a ten-building site, commit to one redundant Standard pair with a single application and no fallback projects, and choose Edge Panel per building only when operators must keep control through an interbuilding outage, within the documented Edge limits.
On this page
- A second network card adds an attachment, not a route
- Option A: one redundant Standard pair over routed paths
- Option B: Edge Panel in each building
- Side by side
- The documented Edge limits that decide each building
- Working the ten-building case: two gateways or ten Edge Panels
- Where a failed request stops
- The decision
- Questions asked
Fitting each building PC with a second network card gives it two attachments and no routing: one card faces the building's devices, the other faces the interbuilding network. A central Ignition gateway still cannot poll a device on a subnet nothing routes to, and a PC forwarding between its own cards is a router nobody documents, monitors or spares. The decision is where device communication terminates. For this site the answer is one redundant pair of Standard gateways with routed paths to every building subnet, one application and no fallback projects. Edge Panel in every building wins only when operators must keep control through an interbuilding outage, and each building then has to fit the documented Edge limits.
A second network card adds an attachment, not a route #
Two separate paths carry this design, and they fail separately. Browser-to-gateway traffic is the first: a Perspective session that opens proves the operator's browser can reach the gateway and nothing else. Gateway-to-device traffic is the second: the driver's poll has to leave the central host, cross the interbuilding network, get routed into the building subnet, reach the device, and the response has to find its way back. An application that loads while its tags sit in bad quality is the signature of a working first path and a broken second one.
Nothing about the second card changes that. The device-facing subnet stays inside the building unless a router delivers it or the building VLANs are trunked to the central servers. Test from the host that initiates the traffic: device reachability from a building PC proves nothing about the central gateway, and a ping proves nothing about whether the driver's port is permitted.
Option A: one redundant Standard pair over routed paths #
Run two Standard gateways as a redundant pair, host one Perspective application, and point every building's browsers at the pair. No local projects exist, so there is nothing to fail over and nothing to version building by building.
The network then has three jobs. Reachability comes first: a forward route from each gateway to every building subnet, a return route from every building subnet back to the central one, and access rules scoped to the driver ports in use, because industrial subnets require a gateway for routed traffic. The alternative shape is trunking: bring the building VLANs to the central servers so each gateway sits on every building network, and pick whichever shape the site's segmentation policy allows. On the physical side, pull two links to every building and configure a loop-prevention mechanism, rapid spanning tree being one candidate, before the second cable connects; two cables alone are not redundancy, and unmanaged parallel links build a loop. For the topology patterns behind that choice, compare a multi-building network design with two gateways on one subnet in this dual-gateway network walkthrough.
Two boundaries to keep straight. The redundant pair covers a gateway failure, not a cut path, and an Edge gateway cannot serve as one half of that pair, as why an Edge and Standard gateway pair is not high availability explains. When an interbuilding link fails under this option, the building's screens are gone until the link returns; the process keeps running on its controllers either way, because machine safety stays hardwired and independent of the screens. What this option trades away is visibility, not the safety chain.
Option B: Edge Panel in each building #
Each building PC hosts Edge Panel, with the install choice covered in run Ignition Edge Panel natively or in Docker on an industrial PC. The local Perspective application reads the local tags, so operation inside the building survives an interbuilding cut, and the central pair stays for site-wide views and history.
Data flows one way. The central gateway adds each building as a remote tag provider and reads its tags, the pattern covered in pull Ignition Edge tags to the main gateway with a remote tag provider. Edge cannot connect to remote tag providers itself, and that kills the one-application idea: a local project cannot point at the central gateway for another building's tags, so screens for other buildings exist only on the central application. EAM can distribute and manage the local projects, the same mechanism that pushes UDT definitions to Ignition Edge gateways with EAM, but they remain separate projects, one per building, designed, tested and versioned alongside the central one.
Design around two more behaviors. The building Edge writes history into its own local store, and the central historian records only what the central gateway can read, so an interbuilding outage becomes a gap in central history. And when the central application is unreachable, nothing switches the operator over automatically: the local application is launched by hand.
Side by side #
The two options, plus the collection-only variant for buildings where nobody operates:
| Approach | Device data path | Screens in the building | Interbuilding link fails | What must be true |
|---|---|---|---|---|
| One redundant Standard pair | Gateways poll devices over routed building subnets | Browsers run the central Perspective application | Building loses its screens; controllers keep running | Forward and return routes from both gateways to every subnet, or VLAN trunks to the gateways |
| Edge Panel per building | Building Edge collects; the central gateway reads it as a remote tag provider | Local Perspective application on the Edge | Building keeps operating locally; central history takes a gap | Every building passes the Edge limits; local and central projects both maintained |
| Edge collection only per building | Same collection and central read as above | None | Local collection continues; nothing to operate with | Nobody operates in that building |
The collection-only row is what an Edge IIoT gateway on the building PCs would buy: it solves data aggregation and nothing else, so it fits an unattended building.
The documented Edge limits that decide each building #
Option B is granted building by building, against the manual's limits:
| Documented Edge limit | What it means at this site |
|---|---|
| Two concurrent Vision Clients or Perspective Sessions | One operator and one spare per building; a third session cannot run |
| Two device connections by default | Once two devices are configured, the add-device control is disabled, so a third controller is not collectable as shipped |
| A strict 500-tag limit | Tags added above the limit do not work until others are removed |
| 35 days of local history | Longer retention has to come from the central historian |
| No remote tag providers | A local project sees only its own building's tags |
A building that fails any row keeps its devices on routed paths to the central gateways regardless of what the rest of the site does, which is one more reason the routed network gets built either way.
Working the ten-building case: two gateways or ten Edge Panels #
Inputs, with units and where each comes from:
- 10 buildings, 1 PC per building, 2 network cards per PC: the site as you described it.
- A redundant central pair: 2 Standard gateways.
- The manual's Edge limits: 2 concurrent clients, 2 device connections by default, 500 tags, 35 days of local history.
The rule, in words: choose the central pair when both gateways get routed paths to every building subnet and the site accepts that a cut interbuilding link stops that building's screens and control. Choose Edge Panel per building only when local control must survive the cut and every building fits the limits.
Arithmetic, Option A:
- Applications to maintain: 1.
- Gateway licenses: 2.
- Reachability to build and prove: 10 subnets x 2 gateways = 20 gateway-to-subnet paths; each needs a forward and a return route, so 20 x 2 = 40 route checks.
Arithmetic, Option B:
- Applications: 10 local projects + 1 central = 11 to design, test and version.
- Gateway licenses: 10 Edge Panel + 2 Standard = 12.
- Forwarding to monitor: 10 buildings x 1 remote tag provider each = 10 connections.
- The per-building gate: every building must sit inside all four limits listed in the inputs.
Result: Option A totals one application, two gateway licenses and 40 route checks. Option B totals 11 applications, 12 gateway licenses and 10 monitored forwarding connections, and only for buildings that pass all four checks.
Decision: this site is pulling new interbuilding circuits and giving every building its own subnet, and no operating requirement on the table says a building must control its process through an interbuilding outage. Commit to Option A, the redundant Standard pair over routed paths, with dual links, loop prevention and one application. The threshold that flips it is a written requirement for local control during an outage; cross it, and that site moves to Option B building by building, with any failing building's devices left on routed paths to the central pair.
Where a failed request stops #
Whichever option wins, these are the fault boundaries you will actually debug:
- Central pages open, building tags in bad quality: the browser path works and the device path does not. Read the device connection status on the gateway and test reachability from the gateway host itself, not from a building PC.
- Building Edge reads its devices, central application shows nothing from that building: the remote tag provider connection. Check the forwarding connection on the central gateway and the quality of the received tags.
- Central application unreachable, building operating normally: the interbuilding path. Under Option B this is the design working; under Option A it is the outage case.
- A local project cannot browse another gateway's tags: expected on Edge. Cross-building screens belong on the central application.
The decision #
For ten buildings, one PC each, new circuits and a subnet per building: build the routed network and run one redundant pair of Standard gateways, with the loop-prevention mechanism configured before the second link connects, forward and return routes to every subnet documented and tested, and one Perspective application for the whole site. The local-project design is engineering you buy back only with a requirement to control through an outage, and the limits table decides whether a building is even eligible for it. Keep the building PCs as hosts, not routers.
Questions asked
Do operator annotations reach the building gateway from the central application?
No. Remote tag provider connections carry tag values both ways, but annotations to the remote gateway are not supported. An annotation entered in the central application stays there, so keep annotation-driven workflows in the application the operator actually works in, and remember the building Edge cannot connect to any remote provider at all.
Does Edge support the same Perspective components as a full gateway?
The core Perspective components behave the same on Edge, so screens built only from core components port unchanged. Components that come from third-party modules are not available on Edge, so a local project that uses one will not run there. That is the feature gap to check before designing the per-building projects.
What does the operator do when the interbuilding link fails?
Under the central design, nothing locally until the link returns. Under Edge Panel, the operator launches the local application by hand, because Perspective has no automatic fallback to a local gateway. A Vision local fallback client does reconnect to a local gateway on its own, so a Vision-based interface can cover this case without operator action.
How long does an Edge gateway keep local history?
Local history stops at 35 days. Anything older exists only where the central historian recorded it, so a forwarding connection that fails quietly turns into central history gaps. Monitor the provider connection itself, not just the devices it serves.
Can one Edge gateway collect a building with three controllers?
Two device connections is the documented default: once two devices are configured, the add-device control stops offering more. Give the third controller to the central gateways over the routed interbuilding network instead of forcing it through the building Edge, and count device connections for each building before committing to the per-building design.