Short answer

Treat the customer LAN as optional. Put an edge PC and a cellular router inside the machine's own cabinet, run a site-to-site OpenVPN tunnel to your office, and log the curing run read-only. Interlocks and protective shutdown stay in the furnace controller, so a dropped tunnel never touches process safety.

On this page
  1. Why does asking plant IT for LAN access stall a curing job?
  2. What architecture monitors a furnace without joining the plant network?
  3. How much cellular data does a 3 to 4 day curing run use?
  4. What does IEC 62443 require from a cellular monitoring conduit?
  5. Which functions stay off the cellular path in a furnace installation?
  6. Which hardware goes in the cabinet for cellular furnace monitoring?
  7. How do you prove the curing record before the furnace leaves your floor?
  8. Questions asked

When the customer's IT department will not put your furnace on their network, stop waiting for an approval that may never come. Build the monitoring path as part of the machine: an edge PC and a cellular router in the furnace's own cabinet, a site-to-site OpenVPN tunnel back to your office, and read-only logging of the curing run. A 3 to 4 day cure documents reliably this way, on a data budget you can compute before the first shift. The controller keeps every interlock and protective shutdown; the cellular path only watches. This article covers why the LAN request stalls, the architecture that removes it, the data math, what IEC 62443 asks of the tunnel, what stays local, the cabinet hardware and the acceptance test to run before the machine leaves your floor.

Why does asking plant IT for LAN access stall a curing job? #

Because a monitoring request lands in the IT department's change queue with no owner and no deadline, the practical answer is to stop asking: build the monitoring network as part of the machine, on its own cellular path, so the cure never waits on an approval.

The request is routine for you and a policy decision for them: a firewall rule for an unknown OEM computer, an onboarding process, a guest network that forbids machine traffic, a change board that meets after your cure window closes. None of that is hostility. It is work with no owner on their side and no way for you to schedule it.

The fixes that fail aim at the wrong layer. Re-running cables or fighting the guest Wi-Fi attacks signal quality, when the blocker is authorization. Replacing the SCADA package attacks software, when the blocker is routing. Publishing the controller straight to the internet attacks nothing and creates an exposed PLC, which is worse than waiting.

So the decision is architectural, not diplomatic: treat plant LAN access as optional from the quotation stage, and give the machine its own monitoring network. If IT later grants a path, add it as a second conduit. Never make the cure depend on it.

What architecture monitors a furnace without joining the plant network? #

Four boxes in the machine's own cabinet: the furnace controller, an edge PC, a cellular router and one VPN endpoint at your office, joined by a single site-to-site OpenVPN tunnel that carries monitoring traffic and nothing else.

  • Furnace controller — runs the cure, the interlocks and the protective trips on the machine-level Ethernet you built with the furnace; nothing about it changes.
  • Edge PC — joins that machine network, polls the process values, stamps every record at acquisition, writes the history and serves the trend.
  • Cellular router — holds the SIM, runs the OpenVPN client and dials the tunnel out; it accepts no inbound connections from the internet.
  • Office endpoint — one VPN concentrator, the logging database and the alert dispatch, on your side of the internet.

Two properties make this independent of plant IT. The machine side initiates: the router dials out to your endpoint, so nothing at the customer's site needs a routable address or a firewall change. And the conduit is single-purpose: only the logging protocol crosses it. Inside the edge host, keep the read path for monitoring and keep writes with the controller — the same publish-versus-control split we apply in keeping publish and control traffic separate in Node-RED IO data MQTT setups.

The office endpoint does not need dedicated hardware. A small virtual machine behind your firewall serves, and running a remote access VPN from a VM with NAT mode is one working pattern for it.

How much cellular data does a 3 to 4 day curing run use? #

Plan on roughly half a gigabyte: twelve process values logged once a second at about 100 bytes of payload come to about 104 MB a day, so a 4-day run plus encryption overhead lands just under 500 MB.

Worked example, with illustrative inputs: twelve values (six zone temperatures, the setpoint, two blower states, three status flags), one sample each second, 100 bytes of payload per record.

  • 12 values × 100 B = 1,200 B per second
  • 1,200 B/s × 86,400 s = 103,680,000 B ≈ 103.7 MB per day (1 MB = 1,000,000 B)
  • 103.7 MB × 4 days = 414.7 MB of records for one run
  • 414.7 MB × 1.2 for TCP, TLS and MQTT framing ≈ 498 MB — call it half a gigabyte for the run

Sample rate and tag count move the total linearly. At 10-second logging the fixed-rate figure drops to 10.4 MB a day, so a 1 GB allowance covers about 96 days of continuous monitoring; planning on 60 of those days keeps the margin. Deadband logging — transmit on change — cuts a temperature-heavy cure well below any fixed-rate number. Tunnel keepalives of roughly 100 B every 10 seconds add about 3 MB over four days, which is noise.

The decision: a SIM allowance of 1 GB covers a curing job at 1-second logging with about 2× margin over the 498 MB figure, and the edge PC buffers to local storage sized for one full run, so even a total outage holds the documentation.

What does IEC 62443 require from a cellular monitoring conduit? #

It requires the conduit between two zones to carry only the traffic those zones agree on, authenticate both ends and enforce one security policy end to end — a single purpose-built OpenVPN tunnel with certificates on both routers meets that for a read-only monitoring zone.

The series models an OT system as zones, groups of assets that share security requirements, connected by conduits, the communication channels between them, and it requires each conduit to enforce the policy of the zones it joins. Your drawing has two zones and one conduit: the machine cell zone (controller, edge PC, router) and the remote monitoring zone (endpoint, database, alert dispatch), joined by the tunnel.

That maps to four conduit duties. Authenticate both ends with certificates, not passwords. Encrypt everything that crosses. Restrict the conduit to the monitoring protocol and its ports, nothing else. Log what crosses. A single-purpose tunnel satisfies these more cleanly than a shared plant network ever could, because there is nothing else on it to police.

The design also leaves the customer's zones untouched: the conduit begins at the machine's own router and points outward, so no route into their network is added. The controller keeps the discipline we describe in connecting a PLC to the plant network without exposing drives: controller and drive services stay reachable only on the machine network, never from the monitoring path.

If your monitoring design fits on one diagram as two zones and one conduit with certificates at both ends, it will survive both the security review and the audit.

Which functions stay off the cellular path in a furnace installation? #

Every protective function — over-temperature trips, flame supervision, the curing sequence itself, any shutdown that protects the load — stays in the furnace controller, because the tunnel is a documentation service and a dropped link or a lapsed SIM must leave the cure running exactly as before.

Treat that split as the safety boundary of the whole design, not a preference: the monitoring path is documentation, and no protective function may depend on it. The working rule is response time. An action that must happen within seconds executes in the controller, without a network. An alarm that reaches a phone through the tunnel arrives at the speed of a human with a signal, so it starts a response; it never is the response.

The monitoring path has four failure modes and all four must be harmless to the cure: a dead edge PC, a dropped tunnel, an expired certificate, an exhausted SIM. Force each one on your floor before the customer does. Pull the edge PC's power mid-cure and confirm the furnace does not notice. If the logging path runs MQTT over TLS, certificate expiry is the failure that arrives quietly weeks in, and the renewal discipline we describe for MQTT TLS certificates on an edge PC closes it.

Which hardware goes in the cabinet for cellular furnace monitoring? #

Three devices: a fanless industrial mini PC as the logging host, an industrial 4G router that supports an OpenVPN client, and fused, surge-protected power behind them, every item rated for the temperature your cabinet actually reaches.

The logging host is a job for an industrial mini PC: fanless, cabinet-mounted, with the serial and Ethernet ports the controller link needs, rather than a desktop tower running hot in a sealed box. The router needs certificate-based OpenVPN client support in its own firmware and an external antenna connection; the selection questions are the ones we walk through in choosing a firewall VPN for an industrial remote access router.

Feed both devices from the machine's control power through a fused DIN-rail supply, with surge protection on the power feed and the antenna line. Check temperature against the cabinet as built, not against one datasheet: a sealed enclosure in sunlight can pass its rating on paper and cook its contents in service, so every device inside must be rated for what the assembly actually reaches.

Prove cellular coverage at the cabinet's exact location with a test router before installation day. Moving the antenna outside or onto the roof is a routine fix. Discovering a dead zone during the cure is not.

How do you prove the curing record before the furnace leaves your floor? #

Run one full dress rehearsal on your own floor: inject a known value, cut the antenna for an hour, power-cycle the edge PC mid-run, then check that the record still shows the right tag, the right value and its true local timestamp with only the planned gap.

  1. Inject a known value on a known tag at a known local time, then find exactly that record — tag, value, timestamp — in the office history.
  2. Disconnect the antenna for an hour mid-run and confirm the record later shows the gap with true acquisition timestamps, not backfilled values.
  3. Power-cycle the edge PC mid-run and confirm it resumes and forwards the queued records.
  4. Drop the tunnel from each side in turn; after an office-side restart the router must re-establish on its own, because the machine initiates.
  5. Open the trend on a phone over the VPN, the way your engineer will read it on site — reaching a Node-RED dashboard from a phone over VPN is that access pattern.

During a run, let the symptom pick the layer:

Symptom Layer to suspect First check
Trend loads, values frozen Acquisition on the edge PC Last acquisition timestamp against the controller's own display
Values live, history has gaps Buffer forwarding or database write Queue depth and database errors around the gap
Tunnel down from the machine Cellular link Router signal level and SIM state before touching tunnel settings
Tunnel down from the office only Office endpoint Concentrator logs for that tunnel's certificate
Alarm in the trend, no phone alert Notification dispatch The dispatch service's own response for that event

Release the furnace to the customer when a rehearsal in which you forced every one of those failures still produced a record that reconstructs the cure — not when a clean bench demo worked once.

Questions asked

Does the machine side of the tunnel need a public IP address?

No. The cellular router at the furnace holds the client role and dials the tunnel out to your office endpoint, which is the only side that needs a reachable address. Carrier networks normally keep the SIM behind private addressing, so the machine side must always be the one that initiates and re-establishes. Set reconnect and keepalive timers with that direction in mind.

What happens to the curing record when the cellular signal drops mid-run?

Nothing is lost if the edge PC buffers locally. Each record is stamped at acquisition, queued during the outage and forwarded when the tunnel returns, so the trend shows a visible gap at true timestamps instead of backfilled values. Size the buffer to hold at least one full curing run, so even a total outage cannot destroy the documentation.

Can remote setpoint changes be added to the same tunnel later?

Only as a second, deliberately built conduit. The first installation is read-only; a write path needs its own authentication, explicit authorization on the controller and acceptance testing of every command the controller will honor. The controller's own limits and interlocks must judge a remote command exactly as they judge a local one, and the monitoring host must never gain write rights by accident.

What should be settled with the carrier before installation day?

Three things. Coverage at the exact cabinet location, proven with a test router on site. A data allowance sized from your logging math with margin. And an access point name configuration that permits outbound connections only, so the SIM cannot accept inbound sessions. Ask how the SIM is suspended and reactivated too, because a cure can start weeks after the last check-in.

Keep reading

  • How-to

    Segmenting edge platform networks for data, BMC and OS traffic

    Three interfaces are the right starting point, but they isolate nothing by themselves. Put data on the industrial segment, BMC and OS management on a restricted management segment reached only from named administrative systems, feed updates through approved destinations instead of the open Internet, and disable host forwarding so the edge computer cannot bridge zones. IEC 62443-3-2 frames these boundaries as zones and conduits; every crossing needs an explicit rule.

    OT cybersecurity

  • Troubleshooting

    Edge gateway shows offline: check the 3.5.16 requirement

    An edge gateway that flipped from green to offline most likely sits on 3.5.15 while the Automation Server lists Edge Gateway 3.5.16.0 or higher as the runtime system requirement. Read the installed version first, then remove and re-add the gateway, replace it through the service tool, update to 3.5.16.0 or higher, and escalate through a CODESYS Store support question if it stays red.

    Edge computing and IIoT

  • Troubleshooting

    Ping works but PLC program download fails over remote access

    ICMP success proves only the routed IP path, not the programming session. A download opens separate query and download connections on documented TCP and UDP ports, and broadcast discovery does not cross a routed VPN. Point the controller's default gateway at the remote-access router LAN address, permit both programming ports to the controller LAN IP, and add the controller manually by IP.

    Remote access and virtualization