Troubleshooting
Why the IIoT Connector Save button stays disabled without a license
Short answer
A disabled Save control does not prove a license fault: confirm the editor holds a valid pending change and the session has write permission first, then read the in-application licensing status. An inactive entitlement is fixed through the vendor's Service → Software registration route, and on a VMware Ubuntu guest the installation identifier and the clock must stay stable for the evaluation license to hold.

On this page
- Is a greyed-out Save button proof of a licensing fault?
- How do you read the licensing status inside the connector?
- How do you request the IIoT Connector trial license?
- Does the Ubuntu virtual machine keep the activation?
- How much of the evaluation window does a wrong guest clock burn?
- Is the remaining fault in saving or in the data connection?
- Questions asked
You installed IIoT Connector on an Ubuntu guest under VMware, the installation is not activated, and the Save control on the configuration screen is grey. The grey control alone does not prove the license is the cause, but an installation with no evaluation license applied has no entitlement at all, and that is the first state to fix: the documented evaluation license allows unrestricted use for a limited window and is requested through Service → Software registration on the B&R website. Work the checks below in the order the fault presents: pending edit and validation first, licensing status second, the virtual machine's identity and clock third, and only then the data path downstream.
Is a greyed-out Save button proof of a licensing fault? #
No. A disabled Save control only tells you the editor is not offering a commit: the configuration may be unchanged, incomplete, invalid or read-only for the current session, and an unlicensed installation is one of those states, not the only one.
Start on the configuration screen, not the controller connection. Configuration editors commonly withhold their save action when nothing changed, when a field failed validation, or when the session lacks write access; the exact enable conditions belong to the installed release, so record the exact screen label and any message shown next to it before changing anything.
| Reading to take | Where to look | Next check |
|---|---|---|
| Pending configuration change | The open editor | If nothing changed, make one reversible, valid edit and watch the control. |
| Missing or invalid entries | Field messages and page notifications | Correct the identified entry; note whether the control becomes available. |
| Read-only session | Session permissions and application messages | Sign in with an authorized configuration account and repeat the edit. |
| Inactive license | The application's licensing information | Request the evaluation license as described below. |
If the session itself is the blocker — a lost or unknown configuration account — the reset route is covered in recovering lost access to an IIoT edge connector; a restored account still needs the license branch finished afterward.
How do you read the licensing status inside the connector? #
Read the licensing status in the application's own licensing information: an inactive entitlement is resolved through the vendor's registration route, while an active one sends you back to editor validation and session permissions.
Installing the software and being entitled to use it are different states. The installation establishes the application files and services; activation establishes the entitlement that licensed functions check. Keep three milestones apart:
- The registration request was accepted.
- A license was issued for the installation.
- The running installation recognizes that license.
An installation can sit at the second milestone while the screen still shows inactive; only the status read from the running application decides the third. A license issued for another product or feature is not a substitute for the entitlement the connector itself requires.
Note which behavior you see at the moment of saving. A control that never enables means no save request reached the application service at all. A control that enables and then returns an error means the request was accepted and failed during validation or persistence — a different diagnostic branch, handled in the last section. If another edge runtime on the same box also sits in trial, why Ignition Edge plugins stay in trial before a license sorts that product's milestones the same way.
How do you request the IIoT Connector trial license? #
Request the evaluation license on the B&R website under Service → Software registration; the documented evaluation license allows unrestricted use of the connector for 90 days, and after that window a new license is required.
- Record the installed product name and software version from the application's identification information.
- Open the B&R website and select Service → Software registration.
- Request the trial for the installed IIoT Connector product and supply the registration information the process asks for. Where an installation identifier is required, take it from the documented licensing interface of the installation being tested — not a hostname, and not an identifier from another machine.
- Retain the issued entitlement together with its activation instructions.
- Apply the license with the documented procedure for the installed release.
- Read the application's licensing status again and confirm the running installation recognizes the entitlement.
The same registration route also covers the commercial license, which is valid for one year and renews; put that step on the plan before the evaluation window closes if the connector stays in service.
Does the Ubuntu virtual machine keep the activation? #
Yes, as long as the installation identifier and the guest clock stay stable: machine-bound entitlements are checked against the identifiers the guest presents, and a time-limited license compares itself with the guest's date.
Keep the virtual machine configuration unchanged while you apply and test the license. Cloning, restoring a snapshot or changing virtual hardware can alter the identifiers the guest presents, depending on the licensing implementation. If activation is accepted and the application later reports inactive, compare the current installation identifier with the one submitted during registration, and read the guest's date and time in Ubuntu's system settings; correct a wrong clock through normal system administration.
If the entitlement is rejected outright, use B&R's official support channel and provide the product version, the virtualization environment, the exact licensing message and the registration reference. Do not modify activation files or machine identity to force acceptance; that destroys the very state you are trying to prove.
How much of the evaluation window does a wrong guest clock burn? #
A guest clock that reads 60 days ahead cuts the usable window on a license issued 2 May 2025 to 30 days, because the entitlement expires on 31 July 2025 whatever the virtual machine reports.
Worked example, with illustrative dates. The license is issued on 2 May 2025 with a 90-day window. Expiry = 2 May 2025 + 90 days: 29 days left in May + 30 days in June + 31 days in July = 90 days, so the license runs to 31 July 2025. At first launch the Ubuntu guest reads 1 July 2025 because its clock was never corrected. Elapsed as the license sees it: 31 days (2 May to 2 June) + 29 days (2 June to 1 July) = 60 days. Remaining: 90 − 60 = 30 days. Decision: before applying the license, set the guest clock to the real date through normal Ubuntu time administration and keep it synchronized, so the full window is available for the evaluation.
Is the remaining fault in saving or in the data connection? #
After the license is recognized, repeat the same valid edit: if the save control stays disabled the fault is still editor validation or session permissions, and if saving works but no data flows, the fault sits downstream of the connector.
Run the branches in this order and stop at the first one that reproduces:
- The control enables after activation: the license was the cause. Continue the evaluation and schedule the commercial license before the window closes.
- The control stays disabled: return to the readings table in the first section; the license branch is finished and did not unblock the editor.
- The control enables but returns an error: capture the exact message and read the application logs for the same attempt; the message points to configuration storage permissions or the application service.
- The configuration saves but no data arrives: a different fault. Check the configured endpoint, the communication driver, controller accessibility and the selected data item; the connector's quality or connection diagnostics distinguish an unreachable controller from an invalid item reference. A healthy value inside the connector with an empty downstream display points at the consumer's binding, not the connector.
That last branch closes the case: once the configuration is retained and the license status reads active, a greyed-out control is no longer part of the fault, and the investigation belongs to the data path.
Questions asked
Can the evaluation license be extended once it expires?
No. The documented terms allow unrestricted use during the evaluation period only, and once that period ends a new license is required. Request another evaluation license or the commercial license through the same software registration route on the vendor website; the commercial license is valid for one year and renews.
Does cloning the virtual machine carry the activation to the copy?
Not reliably. A machine-bound entitlement is checked against the identifiers the guest presents, and a clone, a snapshot restore or a virtual hardware change can alter them. Run the trial on the registered virtual machine itself, and if a clone reports the license inactive, compare its installation identifier with the one submitted during registration before contacting support.
Is an evaluation license acceptable for a running production line?
No. Evaluation mode exists for testing, and the trial terms restrict use to that evaluation. A connector that feeds production data or a live cloud application needs the commercial license activated before you rely on it, confirmed by the same licensing status read showing the installation recognizes that entitlement.
Where does the registration process get the installation identifier?
From the connector's documented licensing interface on the machine being registered. Do not substitute the virtual machine's hostname, the hypervisor's identifier or a value copied from another installation, because the issued entitlement is checked against the installation that supplied it.

